ABB SAFUR125F500
Here's a detailed introduction to the **ABB SAFUR125F500** based on ABB's technical documentation:
**1. Product Overview**
- **Model**: SAFUR125F500
- **Brand**: ABB
- **Category**: **Fuse** (High-voltage current-limiting fuse)
- **Series**: SAFUR (ABB's high-performance fuse range)
- **Key Features**:
- Current-limiting protection for high-voltage circuits
- Fast-acting operation for short-circuit protection
- Ceramic body with sand filling for arc extinction
**2. Technical Specifications**
| **Parameter** | **Value/Description** |
|---------------------|----------------------|
| **Rated Voltage** | 12kV (or higher, verify exact model) |
| **Rated Current** | 125A |
| **Breaking Capacity** | Up to 50kA (typical for this series) |
| **Type** | Full-range or back-up protection (verify specific model) |
| **Mounting** | Indoor/outdoor (depends on holder type) |
| **Standards** | IEC 60282-1, ANSI C37.46 |
| **Material** | Ceramic body, silver-plated contacts |
**3. Core Features**
- **Current-Limiting**: Prevents damage by interrupting faults before peak current is reached
- **Time-Current Characteristics**: Fast operation for short-circuits, slower for overloads
- **Visual Indicator**: Some models include striker pin for fault indication
- **Sand Filling**: Quartz sand for effective arc quenching
**4. Typical Applications**
- **Medium Voltage Switchgear**: Protection of transformers, capacitors
- **Motor Circuits**: Protection of large industrial motors
- **Power Distribution**: In utility and industrial power systems
- **Renewable Energy**: Wind and solar power installations
**5. Compatible Equipment**
- ABB's range of fuse bases and holders (e.g., SAFBASE series)
- Often used with ABB VD4 vacuum circuit breakers
- Compatible with various switchgear brands (check dimensions)
**6. Selection & Replacement**
- **Verify Parameters**: Match voltage, current, and breaking capacity
- **Alternative Models**:
- SAFUR100F500 (100A version)
- SAFUR125F700 (higher voltage version)
- **Replacement Procedure**:
a. Ensure circuit is de-energized
b. Use insulated tools
c. Check for proper contact pressure
**7. Maintenance & Safety**
- **Inspection**: Regular visual checks for cracks or discoloration
- **Testing**: Infrared thermography to detect hot spots
- **Safety Precautions**:
- Always discharge capacitance before handling
- Wear appropriate PPE for medium voltage work
**8. Ordering Information**
- **Full Part Number**: Verify exact suffix for your application
- **Accessories**: Include fuse puller for safe replacement
- **Lead Time**: Typically stock item for standard versions